Overview
A healthy reverse osmosis system produces water with TDS between 5 and 50 ppm — typically 90–98% lower than your feed water. TDS is the single best diagnostic for membrane health and a reliable early warning of membrane failure.
What TDS Actually Measures
Total Dissolved Solids (TDS) is the sum of all inorganic ions and organic compounds dissolved in water, expressed in parts per million (ppm) or milligrams per liter (mg/L). The meter reads electrical conductivity and converts it using a standard conversion factor (NaCl scale, 0.5). TDS does not measure bacteria, chlorine, or organic contaminants.
Healthy TDS Ranges by Feed Water
For city water (typically 100–400 ppm feed), expect 5–30 ppm permeate. For hard well water (500–1500 ppm feed), expect 30–80 ppm permeate. For brackish water (over 2000 ppm), residential RO is not recommended — use a commercial system. Permeate TDS should always be 90–98% lower than feed TDS.
Calculating Membrane Rejection Rate
Rejection % = ((Feed TDS − Permeate TDS) / Feed TDS) × 100. Example: feed 300 ppm, permeate 15 ppm → rejection = 95%. New TFC membranes deliver 95–99% rejection. Replace when rejection falls below 85% or when permeate TDS doubles from baseline.
When Low TDS Is Misleading
A burst storage tank bladder can leak pressurization air into permeate, lowering apparent TDS but contaminating water with rust and bladder material. Always pair TDS testing with visual inspection and periodic third-party lab testing for full-spectrum contaminants.
TDS-Based Maintenance Schedule
Test permeate TDS monthly. Track readings in a logbook. Triggers: 25% rise in permeate TDS = check pre-filters and feed pressure. 50% rise = replace membrane. Sudden drop = check tank bladder. Quarterly testing of feed water TDS catches utility water quality changes (especially in summer when surface water TDS rises).
Should You Remineralize Low-TDS RO Water?
Optional. Pure RO water (under 10 ppm) tastes flat and slightly acidic (pH 6.0–6.5). A remineralization cartridge ($25–40) adds calcium carbonate and magnesium, raising TDS to 30–60 ppm and pH to 7.5–8.5. This improves taste and prevents copper pipe corrosion in homes with old plumbing.
TDS vs Other Water Quality Metrics
TDS is one of several quality indicators. For complete water quality assessment, also measure: pH (6.5–8.5 ideal), hardness (under 60 ppm soft, over 180 ppm hard), chlorine (under 0.5 ppm), and lead/heavy metals via a lab test. TDS alone cannot detect organic contaminants, pathogens, or PFAS.
Bottom Line
Use this guide as a reference, then match the right approach to your specific water test results, budget, and household needs. The FAQs below answer the most common follow-up questions.
Related Resources
More: how reverse osmosis works · 14 parts of RO system · how to flush RO · membrane replacement · best water test kits · best RO systems
Authority resources: best home water filters · best RO systems · best whole house filters · best water softeners · best well water filters · best water test kits · lead in water · PFAS contamination · fluoride in water · chlorine in water · how to choose a filter · local water quality