Overview
Chromium-6, the carcinogen made famous by the Erin Brockovich case, is detected in the tap water of more than 200 million Americans according to EWG sampling. Concentrations above the California public health goal of 0.02 µg/L are now the rule rather than the exception, and the EPA has not yet set a federal MCL specifically for hexavalent chromium.
What Is Chromium-6 (hexavalent chromium)?
Chromium-6 (Cr⁶⁺) is the hexavalent oxidation state of chromium — a heavy metal that occurs naturally in some rocks but is mostly released into drinking water through industrial discharge, cooling tower runoff, and chrome plating waste. It is far more toxic than the trivalent chromium-3 form (a trace nutrient). Chromium-6 is colorless, odorless, and tasteless in water.
Where Does It Come From?
Major sources include leaching from natural mineral deposits (parts of the Southwest), runoff from steel and pulp mills, leather tanning waste, chromate-treated cooling towers, and erosion of natural deposits. Hinkley, California — the Erin Brockovich case — was contaminated by PG&E cooling-tower discharge in the 1960s. Today, the worst US hotspots include Phoenix, Norman OK, parts of Riverside CA, and industrial corridors of New Jersey.
Health Effects
The National Toxicology Program classifies chromium-6 as a known human carcinogen via inhalation and a probable carcinogen via ingestion. Chronic oral exposure is linked to stomach and intestinal tumors in animal studies. Acute high-dose exposure causes liver damage, kidney failure, and gastrointestinal bleeding. The California OEHHA public health goal is 0.02 µg/L for negligible cancer risk.
How to Test for It
Standard EPA Method 218.7 testing requires a certified lab — typical cost is $40–$75 per sample via SimpleLab Tap Score or NTL. Home test strips do not detect chromium-6. Sample first-draw cold tap water in lab-supplied bottles. Levels above 0.5 µg/L warrant filtration; above 10 µg/L (the proposed federal MCL discussed in 2024) warrant immediate action.
How to Remove It
The most effective home removal methods for chromium-6 are reverse osmosis (95%+ rejection), strong-base anion exchange resin (90%+), and reduction-coagulation with stannous chloride (industrial only). Activated carbon does not remove chromium-6. NSF/ANSI 58 certified RO systems explicitly listing hexavalent chromium include the Waterdrop G3P800, AquaTru Classic, and Home Master TMHP HydroPerfect.
EPA Limits & Regulations
The current EPA enforceable limit is 100 µg/L for total chromium (combined Cr-3 and Cr-6) — set in 1991 and widely considered outdated. California became the first state to set a Cr-6-specific MCL of 10 µg/L in 2014, then proposed lowering to 1 µg/L in 2024. The federal EPA published a draft Cr-6 MCL of 10 µg/L in late 2024; finalization is expected by 2027.
Bottom Line
Chromium-6 is a serious carcinogen present in most US tap water at concentrations far above the negligible-risk threshold. If your municipality reports detectable hexavalent chromium (check EWG Tap Water Database), install an NSF 58 certified reverse osmosis system at the kitchen sink. RO is the only practical, verifiable home solution.
Related Resources
For deeper exploration: best RO systems · best water test kits · does RO remove arsenic · best heavy metal filters · local water quality.