Reverse Osmosis Installation Guide

Reviewed by Jason Carter

A clear, step-by-step walkthrough for fitting an under-sink reverse osmosis system with basic tools, plus the checks to make before first use and the signs that the job needs a plumber.

Check these before you buy or start

Five minutes of measuring saves a second trip to the store.

  • Measure the cabinet and note where the disposal, pipes and an outlet are.
  • Check your water pressure against the system's minimum.
  • Find a spare sink or counter hole for the faucet, or plan to drill one.

Quick answer

Most under-sink RO systems can be installed by a handy homeowner in an afternoon. You tap into the cold-water line, mount a small faucet, connect a drain saddle to the sink drain, place the filters and tank, and join everything with push-fit tubing. Then you fill and drain the first tank before drinking. Call a plumber for stone counters, missing shut-off valves or anything that needs a code inspection.

Before you start

  • Space: a tank system needs room for the filter unit and the tank side by side, plus space below the housings to unscrew them. Tankless units are smaller but usually need a power outlet.
  • Pressure: check the system's minimum (many list around 40 psi). Low pressure means slow filling and more water to the drain; a booster pump can help.
  • Shut-off valve: you need a working cold-water valve under the sink. If there is none, or it will not close fully, fix that first.
  • Faucet hole: look for a sink knockout or an unused sprayer or soap hole. Drilling stainless steel is manageable; stone and quartz are best left to a pro.
  • Your water: on a well, or with very hard water or iron, the RO may need pretreatment to protect the membrane. A water test tells you before you buy.

Tools and parts

Tools

  • Adjustable wrench and screwdriver
  • Drill and the bit size your kit lists
  • Tubing cutter or sharp utility knife
  • Thread seal tape
  • Bucket, towels and a flashlight
  • Optional: basin wrench, pressure gauge

Usually in the kit

  • Filter unit with pre-filters, membrane and post-filter
  • Storage tank and tank valve (tank systems)
  • RO faucet, often with an air gap
  • Feed-water adapter and drain saddle
  • Colour-coded tubing and clips

Step-by-step installation

Every kit is a little different, so keep your manual open and trust its diagram over any general guide, including this one.

  1. Shut off the water and plan the layout

    Close the cold-water shut-off valve under the sink and open the cold tap to release pressure. Put a bucket and towels underneath. Decide where the filter unit, tank and faucet will go so every tube can reach without kinks.

  2. Fit the feed-water adapter

    Disconnect the cold supply line from the faucet, add the feed-water adapter (a tee with a small valve) according to your kit, and reconnect the faucet. Leave the RO feed valve closed for now.

  3. Mount the RO faucet

    Use a spare sink or counter hole, or drill one to the size your kit specifies. Fit the faucet with its washers and nut, and attach the air gap if your faucet has one.

  4. Fit the drain saddle

    Clamp the drain saddle onto the sink drain pipe above the trap, and on the opposite side from a disposal if you have one. Drill through the pipe using the saddle as a guide and tighten it evenly so the gasket seals.

  5. Place the filter unit and tank

    Mount the filter manifold on the cabinet wall or set it where the kit suggests, leaving room below to change filters. Stand the tank upright and fit its valve with thread seal tape. Install the filters in the order shown in the manual.

  6. Connect the tubing

    Follow the kit's diagram for the feed, tank, faucet and drain lines. Cut each tube square, push it fully into its fitting until it stops, add any locking clips and tug gently to check it is seated.

  7. Turn on, flush and check for leaks

    Open the cold valve and the RO feed valve, then the tank valve. Check every joint for drips. Let the tank fill, then drain it completely through the RO faucet, as the manual instructs, before drinking the water. Check for leaks again over the next day.

Fixing common install problems

Leaking fittings

Turn off the water and release pressure. Recut the tube square, push it fully home, refit any clip and check the O-rings in the filter housings.

No water from the faucet

Make sure the feed valve and tank valve are open. A new tank can take a few hours to fill.

Very slow filling

Check your water pressure, then the pre-filters for clogging. Low pressure may need a booster pump.

Water running to the drain all the time

The tank may not be building pressure. Check the tank's air pressure when empty against the manual, and the system's shut-off valve.

Gurgling at the faucet or drain

Often normal on air-gap faucets. Make sure the drain line runs downhill without dips or kinks.

After the system is running, keep it on schedule with our RO maintenance guide.

DIY or hire a plumber?

Do it yourself if

  • You have a working shut-off valve under the sink
  • There is a spare faucet hole, or a stainless sink to drill
  • The drain is a standard sink trap
  • You are comfortable following a diagram

Call a plumber if

  • You need to drill stone or quartz
  • There is no shut-off valve, or it leaks
  • The drain is unusual or crowded by a disposal
  • You are running a line to a fridge far away, or local code requires a licensed install

Labour costs vary by area, so get a quote that says whether parts like a new valve or air-gap faucet are included.

RO systems to compare

Two under-sink systems that use standard push-fit connections and come with their own faucet. Open each deal for the current price and check the dimensions against your cabinet.

iSpring RCC7AK 6-Stage RO System
RO and Remineralization Pick

iSpring RCC7AK 6-Stage RO System

Why we recommend it

A six-stage under-sink RO system with a storage tank and a final stage that adds minerals back. It needs a drain connection and room for the tank; check the cabinet space and iSpring's pressure range before buying.

Compare sizing, treatment options and ongoing costs in our best reverse osmosis systems guide.

Aquasana Tankless Reverse Osmosis System (800 GPD)
Tankless RO Pick

Aquasana Tankless Reverse Osmosis System (800 GPD)

Why we recommend it

Aquasana's tankless system pairs a Claryum filter stage with an RO membrane and skips the storage tank, so it leaves more cabinet room. It needs a power outlet under the sink as well as a drain connection and faucet hole; check both before buying.

Compare sizing, treatment options and ongoing costs in our best reverse osmosis systems guide.

Bottom line

Installing an under-sink RO system is a manageable weekend job: plan the layout, fit the feed adapter, faucet and drain saddle, connect the tubing exactly as the diagram shows and flush the first tank. Measure your cabinet and check your pressure before you buy, and call a plumber for stone counters or awkward plumbing.